A small problem can take out the whole unit
A compressor is built to run with the right amount of refrigerant moving through it, carrying oil along for lubrication. Low charge from a slow leak starves it of both. Keep running it that way and the compressor overheats and wears from the inside, where nobody can see it happening. A capacitor that's gone weak makes the motor pull harder to start and run. That heat has nowhere to go but back into the motor windings, and a motor that overheats enough will burn out for good. The part that was cheap to replace on its own gets expensive once it takes something bigger down with it.