Coil clean, air moving
A healthy outdoor unit sits open on the pad, coil fins clear, air passing through on all sides. In this state the unit defrosts itself on a normal cycle and never builds up ice, even on the coldest nights.
A frozen heat pump is almost always trying to tell you it can't get enough warm air moving through the outdoor coil. Cold Gwinnett County nights make this worse, because the colder the air outside, the harder the coil has to work, and the easier it is for ice to build once something is already off. Low refrigerant is a common cause, and so is a dirty outdoor coil, a failed defrost control, or an outdoor fan that has stopped turning. The system should run its own defrost cycle every so often to melt off any frost before it builds up. When that cycle isn't happening right, ice keeps adding to ice. Running the system while it's iced over won't clear it and can stress the compressor, so it's worth shutting it off and switching to backup heat if you have it until someone can look at what's actually failing underneath that ice.

A healthy outdoor unit sits open on the pad, coil fins clear, air passing through on all sides. In this state the unit defrosts itself on a normal cycle and never builds up ice, even on the coldest nights.

Dirt and debris packed into the fins choke off airflow, and the coil runs colder than it should. Once ice starts to form over the fins, less air gets through and the ice builds faster, until the unit can't defrost on its own.
Winter nights average 34°F
Overnight lows near 34°F mean your outdoor coil spends hours right at the edge of freezing, where frost forms fastest if airflow is already weak.
Heat runs November through April
With heat running November through April, that coil goes through months of defrost cycles, and any airflow problem gets more chances to turn into ice.
Cooling runs May through September
Once cooling starts in May, the unit works in reverse and frost on the coil is no longer a sign of trouble, so the window to watch is the six cold months before it.
NOAA nClimDiv 1991-2020
Your heat pump runs a defrost cycle on purpose. Every so often it reverses itself, sends hot refrigerant through the outdoor coil, and melts off any frost that built up while it was heating your house. The outdoor fan stops during this, so you may see steam or hear the unit sound different for a few minutes. That is normal. A unit that keeps icing over despite this cycle either isn't triggering defrost often enough, isn't staying in it long enough to clear the coil, or doesn't have enough airflow across the coil to begin with. Any of those points to a control board, sensor, or airflow problem a contractor needs to check directly.
A coil low on refrigerant runs colder than it should across its whole surface, not just in one spot. That lower temperature pulls more moisture out of the air passing through, and more moisture means more frost forming faster than the defrost cycle can keep up with. This is why a unit that used to handle cold Gwinnett County nights without trouble can start icing over after months of a slow leak. The ice itself then blocks more airflow, so the coil runs even colder and the cycle feeds itself. A contractor checking refrigerant charge is checking for exactly this.




A licensed pro who repairs heat pumps in Gwinnett County gets your request.
There's no charge for the request.
A heat pump that freezes over on a cold Gwinnett County night is telling you something specific. It isn't just the cold. The outdoor coil needs air moving across it and refrigerant at the right pressure to shed the frost it naturally collects when temperatures sit near freezing. When either one falls short, ice builds faster than the defrost cycle can clear it. A working defrost cycle handles this on its own, reversing briefly, melting the coil clean, and starting back up. That's normal and it happens often during a Georgia winter. What isn't normal is ice that comes back within a day, or a coil that stays thick with it even after the system runs its defrost. That points to something concrete: a coil caked with dirt or debris, a defrost control or sensor that isn't triggering the cycle, refrigerant that's low, or an outdoor fan that isn't spinning when it should be pulling air through. Each of these has a different fix, but none of them clear up by waiting. Running the unit with the coil fully iced over puts extra strain on the compressor, the most expensive part to replace, so it's worth switching over to backup heat and shutting the outdoor unit down until it's looked at. A contractor who works on heat pumps through the winter here will recognize which of these is behind your unit's freezing and go straight to checking it.


A frozen outdoor unit needs a technician who can tell whether it's an airflow problem, a refrigerant leak, or a defrost control that's failing, since each calls for different work. A local contractor who services heat pumps through Gwinnett County winters sees this pattern every cold snap and knows where to check first. Request a match and you'll hear from one licensed contractor, not several, so you can get the coil cleared and your heat back on without fielding a string of calls.
The pro who gets in touch is licensed in Georgia and works in Gwinnett County.
You only hire the pro if you want to.