A nighttime street scene featuring a row of lit white colonial-style houses with wrap-around porches, flanked by oak trees draped in Spanish moss.

Heat Pump Repair in Statesboro, GA

Tell us about the job

Takes about a minute. No obligation.

RepairHeat PumpBulloch County, GA
Step 1 of 2

What ZIP code is the job in?

Bulloch County saw 174 severe weather events between 2015 and 2024, and most of that was wind. A heat pump's outdoor unit sits through all of it, with thin aluminum fins and a fan blade exposed to whatever blows through. Wind-driven debris can bend those fins or crack the blade without stopping the system from running. Hail can dent the housing and still leave it limping along, worse on efficiency than it looks from the yard. Statewide, close to a third of Georgia households lost power for a day or more in 2024, and a heat pump that sat dead that long is worth a second look once the power comes back, even if it seems fine.

5 months
November through March, your system heats
6 months
May through October, it cools
39°F
the average winter night it heats against
91°F
the average summer afternoon it cools against
Isometric cutaway illustration of a single-story house showing interior ductwork, an air handler and rooms, with an outdoor condenser unit connected by refrigerant lines on a plain white background.
Your system heats November through March and cools May through October.

NOAA nClimDiv, 1991–2020 normals

A reversing valve that sticks or a defrost board that fails doesn't stop the unit, it just lets ice build on the coil while the compressor keeps trying to work through it.

Shutting the system off at the thermostat when something sounds wrong is a day without heat. Leaving it running can turn a part swap into a compressor failure.

Your heat pump works November through March. A weak part usually fails in the first cold snap, not mid-winter.

Cooling runs May through October
Heat runs November through March
135 damaging wind events from 2015 to 2024

Half the homes in Bulloch County were built in 1995 or later. If your house falls in that half, the heat pump may be newer too, especially if it's the original system. A unit that age usually has years of working life left in it. A bad capacitor, a stuck contactor, a low charge from a small leak, none of that means the system is done. It's usually a repair, not a replacement. The exception is if your home is older than that or the system was swapped out some years back on its own schedule, in which case the age of the house won't tell you much. Check what you actually have before assuming either way.

Had a storm come through? Get the unit checked before winter does.

If your outdoor unit sat through a storm this year, or sat dead through an outage, get it looked at now, before the next cold snap puts a load on whatever got bent or cracked. A dented housing or a fan blade that clipped some debris can still run for months before it fails outright.

Find a contractor
A gray heat pump outdoor unit mounted on a concrete pad next to a residential house with lap siding and stone accents.

Built recently, worth repairing

A heat pump built with a newer house has most of its working life still ahead of it. When a part fails, that's the thing worth fixing, not a reason to think about replacing the whole system. Get the repair done and the unit should carry on for years.

What you can check safely

Look at the thermostat first. Make sure it's set to heat and the set point is actually above room temperature, not just left where it was. Check the breaker for the outdoor unit and the indoor air handler, since a tripped breaker on either side will stop the system cold. Pull the air filter and hold it up to a light. If you can't see light through it, swap it before anyone diagnoses anything else. Walk outside and look at the unit itself. Snow, leaves or a fallen branch pressed against the coil will block airflow and is safe to clear by hand.

What to leave alone

Don't pull the panels off the outdoor unit or the air handler. Capacitors inside hold a charge even with the power off. If the outdoor unit is iced over, don't chip at it or pour water on it. Some icing is normal and clears on its own during a defrost cycle. Ice that never clears is a sign to call someone, not a problem to fix with a hammer. If you smell gas near the air handler or hear grinding or screeching from the outdoor fan, shut the system off at the thermostat and leave it off until someone looks at it.

A heat pump fails in a handful of predictable ways, storms aside. The reversing valve is the part unique to this machine, and when it sticks, the system blows cold air in heating mode or won't switch over at all. The defrost board and sensor are another common failure point, since they're what tells the outdoor unit when to melt off frost and when to go back to heating. If that control fails, ice builds up and never clears. A run capacitor weakens over time and eventually can't get the compressor or fan motor started, so the unit hums for a second and then quits. Low refrigerant almost always means a leak somewhere in the line set or coil, not the system just running low on its own. And a contactor, the switch that sends power to the outdoor unit, can pit and stick from years of cycling on and off, leaving the unit either stuck on or not starting at all.

A diagnostic visit starts with the thermostat and the breakers, the same things worth checking before anyone comes out, then moves to gauges and meters. A tech will connect gauges to check refrigerant pressure, since that one reading points toward a leak, a bad metering device, or a compressor that's struggling. They'll test the capacitor and contactor with a meter rather than guessing from how the unit sounds, because a weak capacitor can still let the fan limp along for a while before it fails outright. On a unit stuck in cooling mode or blowing cold air when it should be heating, they'll check the reversing valve and the coil that controls it. If frost isn't clearing on its own, the defrost board and its sensor get checked next, since that's what tells the system when to switch into defrost and when to stop. Most of this gets done with the panels off and the power locked out, for the same reason it's not something to check yourself.