The tech checks the whole system, not just the symptom

A heat pump that won't heat might have a problem in the outdoor unit, the indoor coil, the reversing valve, or the thermostat wiring. The tech will check refrigerant pressures, measure the temperature split across the coil, test the capacitor and contactor, and look at the defrost cycle before deciding what's actually wrong. A noise or a weak airflow complaint can trace back to a part nowhere near where you hear or feel it.

What the visit tells you

By the end, you should know what failed, why it failed, and whether it's a quick part swap or something that points to the system wearing out. That matters for a heat pump especially, since it runs for both heating and cooling. A bad reversing valve or a failing compressor affects the whole year, not just one season, so it's worth knowing which one you're dealing with before deciding how far to go with the repair.

6 months
November through April, your system heats
5 months
May through September, it cools
35°F
the average winter night it heats against
88°F
the average summer afternoon it cools against
Isometric line illustration of a cutaway house showing interior rooms with furniture, a furnace or air handler with overhead ductwork, and an outdoor condenser unit connected by lines outside the wall.
Your system heats November through April and cools May through September.

NOAA nClimDiv, 1991–2020 normals

A heat pump blowing cold air in heating mode isn't always broken. It could be stuck in defrost or losing the fight against a failing reversing valve.

Watch how long the cold air lasts. A few minutes during defrost is normal. Longer than that, and the valve or the control board needs a look.

Heat pumps here work November through April, then switch straight to summer in May

Cooling runs May through September
Heat runs November through April
132 damaging wind events from 2015 to 2024

Half the homes in DeKalb County were built in 1984 or later. If yours is one of them, the heat pump giving you trouble probably hasn't been running as long as the house itself, especially if it's a replacement unit put in more recently. A newer system with one bad part, a weak capacitor or a failing reversing valve, is usually worth fixing rather than replacing. The compressor and the rest of the system likely still have years left in them. Worth checking when your system was installed before you decide how far to go with a repair.

Storms hit outdoor units hard here. Have it checked, even if it still runs.

DeKalb County had 132 damaging wind events between 2015 and 2024. An outdoor unit sits outside through all of that, and a dented cabinet or bent fins don't always announce themselves as a problem right away. If yours has been through a storm, even one that's still running, it's worth having a tech check the coil and fan before a small issue turns into a compressor replacement.

Find a contractor
A gray air-source heat pump mounted on a concrete pad next to a house with gray vinyl siding, surrounded by gravel and flanked by green shrubs and white hydrangea flowers.

How much life is left in it

If a repair tech is telling you the compressor or the system is too old to fix, that's worth a second opinion, especially on a newer house. Ask what year the system was installed, not just the house. A unit put in within the last several years should still be well inside its working life, and most of that life is spent running fine between the kind of repairs this page is about.

Check these before you call

Look at the thermostat first. Make sure it's set to heat, not cool, and that the set temperature is actually above room temperature. Check the breaker for both the indoor air handler and the outdoor unit. A tripped breaker on just the outdoor side will leave you with a fan blowing air that's never been heated. Look at the outdoor unit itself. Ice covering the coil is normal in small amounts during a defrost cycle, but a unit fully packed in ice means something isn't cycling right. Check that nothing is blocking the outdoor unit, no leaves, no snow, no furniture pushed against it. Airflow in and out of that unit matters as much as airflow through your ducts.

What to leave alone

Don't open the outdoor unit's cabinet or touch anything inside it. The capacitor in there can hold a charge even with the power off. Don't pour water on an iced-over coil to melt it faster. That can crack the coil or get into electrical parts it shouldn't reach. If you smell anything burning or hear a new grinding or screeching noise, shut the system off at the thermostat and the breaker, and leave it off until a tech looks at it. Running a system that's making that kind of noise usually turns a one-part repair into a multi-part one.

Most heat pump failures trace back to a handful of parts. The capacitor that kicks the compressor and fan motors on wears out over time and either fails outright or gives a weak start that strains the motor. The contactor that switches power to the outdoor unit pits and sticks from years of arcing. The reversing valve, the part that switches the system between heating and cooling, can stick in one position, and when it does the system keeps running but stops doing what the thermostat is asking for. Low refrigerant almost always means a leak somewhere in the lines or coil, not the system using it up. The defrost board and sensor misread the coil temperature and either skip a needed defrost cycle or run one that never ends. Dirty coils and clogged filters do not break anything directly, but they make every other part work harder and shorten its life.

A repair is worth doing when one part failed and the rest of the system is sound. A capacitor or contactor replacement doesn't change what kind of shape the compressor is in. Replacement starts to make sense when the compressor itself is the problem, since that part effectively is the system, or when the refrigerant lines or coil are leaking badly enough that one leak repair is likely to be followed by another somewhere else. Age matters less than what's actually failing. A unit that has run fine for years and suddenly needs a reversing valve is still a repair. A unit that keeps coming back for a new problem every season is telling you something about where it's headed, even if each failure was fixable on its own.