Running as a heat pump
This is what normal looks like. The outdoor unit runs, pulling heat from the outside air, and the electric strips stay off. Your bill stays lower because the compressor is doing the work instead of the backup heat.
Your thermostat has an emergency heat setting or light, and you've noticed it's on, or you're wondering what it does. You're not sure if something is wrong with the heat pump or if this is just another setting you can switch on and off. Since most homes in Georgia heat with electricity through a heat pump, understanding this one light matters more here than almost anywhere else.
A heat pump moves heat from the outside air into your house, and that works fine down to a certain outdoor temperature. Below that, or if the outdoor unit itself stops working, a backup heat source takes over, usually electric resistance coils. The thermostat switches to emergency heat automatically when it senses the heat pump isn't keeping up, or you can switch it on by hand if you know the outdoor unit has failed. Either way, the house stays warm, but electric resistance heat costs more to run than the heat pump does. If the light stays on for more than a cold snap, or comes on when it isn't especially cold out, the heat pump itself likely needs a look.





A heat pump pulls heat from the outside air, and below a certain outdoor temperature it can't pull enough to keep up. Frost can also build up on the outdoor coil on cold, damp nights, and the unit needs to shut down to defrost it. Emergency heat switches off that outdoor unit entirely and leaves the electric strips to carry the house until a contractor finds out why the heat pump itself stopped working.

The backup electric strips sit in the indoor air handler and work like a toaster, heating the air directly with electric resistance. There's no compressor, no outdoor coil, no refrigerant cycle, just wire heating up. That's why it costs more to run. A heat pump moves existing heat, but strips make all of theirs from scratch, and in Georgia, where most homes already heat with electricity, that difference shows up fast on the bill.
If emergency heat has been on a while, you might notice the air coming out of the vents feels warmer than usual, almost hot, since it's straight electric heat instead of the heat pump's steadier output. You might also hear the system running longer stretches to hold the same temperature. The bigger thing to watch is why it switched over in the first place. If the outdoor unit isn't coming back on once the weather warms or the frost clears, something's keeping the heat pump itself from running, and leaving it on emergency heat for days at a time means you're paying for strip heat the whole while instead of a repair that gets the heat pump working again.

This is what normal looks like. The outdoor unit runs, pulling heat from the outside air, and the electric strips stay off. Your bill stays lower because the compressor is doing the work instead of the backup heat.

A neglected outdoor unit like this one can fail to come on at all, which is why the thermostat switches to emergency heat and leaves it there. If yours won't switch back once it warms up outside, the outdoor unit needs a look.



Describe your heat pump job once, to one pro.
A local pro who knows heat pumps gets your details and gets in touch.
Asking costs nothing, and the choice to hire stays yours.

The thermostat doesn't choose emergency heat on its own. Either you set it there, or the heat pump's control board put it there because a sensor outside tripped a fault. That might be a defrost sensor that never reads a clear coil, a reversing valve that won't shift, or an outdoor fan motor that's stopped turning. The board locks the compressor out and leans on the strips so the house doesn't go cold while something outside is broken.
That's a real fault, not a setting you can just switch back. Figuring out which part caused it means someone checking voltage, pressures, and sensor readings at the outdoor unit, not guessing from the thermostat. Once you're matched with a contractor who works on heat pumps in your area, they'll ask what the thermostat shows and go straight to the outdoor unit instead of starting from scratch over the phone.

Thermostat calls for heat and signals the outdoor unit to start
Outdoor unit fails to respond because of a tripped fault or a manual switch
Control board locks out the compressor and switches to backup heat
Electric strips inside the air handler heat the air instead



Georgia weather data puts the summer dew point at 68°F on average across June, July and August. That's the heat pump's other job, since the same system pulling moisture out of thick summer air all season is what's supposed to be pulling warmth from cold winter air now. A unit working through muggy summers for years picks up wear on the outdoor coil and the sensors that watch it, and that's often what trips a fault and locks the system onto emergency heat once the cold sets in. If your heat pump keeps dropping into backup heat, that history is worth mentioning to whoever looks at it.
NASA POWER T2MDEW county cells weighted by homes


Emergency heat usually traces back to one part failing on the outdoor unit, not the whole system giving out. The run capacitor gives the compressor the jolt it needs to start, and if it's weak or dead, the compressor just sits there while the control board reads that as a failure and locks it out. A contactor does the same kind of job, closing the circuit that feeds power to the compressor and fan, and when its contacts wear down or pit, the unit stops getting power at all. The high and low pressure switches are safety devices. They watch refrigerant pressure and shut the compressor down before it can damage itself, so a switch tripping doesn't always mean the compressor itself is bad. A slow refrigerant leak will trip that same low pressure switch over time, which is why a unit that ran fine all last winter can start locking out this year without anything obvious changing. The reversing valve is what lets the same unit switch between heating and cooling, and if it sticks, the outdoor unit can seem to run while it's not actually moving heat where it should. None of these show up by looking at the thermostat. A contractor has to check voltage, pressures and amp draw at the outdoor unit to find which one is actually responsible, since more than one of these can produce the exact same emergency heat light.
At 14.74 cents per kilowatt-hour, every hour those electric strips carry the house instead of the heat pump costs more than it should. A stuck fault that goes unfixed for a week shows up on that bill, which is reason enough to get the outdoor unit looked at instead of leaving it on backup heat.
EIA-861 2025 statewide residential average
Emergency heat on your thermostat means the outdoor unit is sitting idle and the electric strips are carrying the whole house. That's a fine way to get through one cold night, but it's not how the system is supposed to run, and the longer it sits that way the more it costs you on backup heat that was only ever meant to fill in. Somewhere outside, a capacitor, a sensor, or a pressure switch tripped the fault that put it there, and that part doesn't fix itself. Instead of searching through contractors, making calls, and explaining the same thermostat light to each one, you can get matched with a contractor who works on heat pumps in Georgia and have them reach out to you directly. That's one call you don't have to make, one explanation you don't have to repeat, and one quote you don't have to chase down on your own while the strips keep running.





Fill out one short form instead of calling around.
No fee to send it, and nothing to sign.